Compact and versaile scale at anywhere. 3kg/6kg with small pan. 15kg/30kg with large pan. Driven by 2 dry cell batteries for 500 hours and / or AC adaptor

FeaturesSpecificationsDimensions
Model Small
Platter size 230 x 200 mm
Capacity and
minimum
graduation
Approval type Non approval type
3kg/1g(0~1.5kg),
2g(1.5~3kg)
6kg/2g(0~3kg),
5g(3~6kg)
3kg/1g
6kg/2g
Weighing
method
Electric resistance method
LCD panel Six digits(7-segment), character height 25 mm
Display information 6-digit weight, battery indicator,dicimal point, net weight indicator , stability indicator, minus sign, and unit of measurement
Net weight measurement Subtraction of tare weight by key input
Power Dry Cell 2 pieces (can be operated for 500 hours with alkaline dry D-Type batteries) or AC Adaptor (No Dry Cell and/or AC adaptor are included in the shipment) Auto Power Off function ( cb be set to 60 min., 20 min., or off)
Operational temperature -5°C ~ 40°C
Outer dimensions
(W x D x H)
236 x 282 x 100 mm
Weight 2.0kg (excluding batteries)
Approvals OIML,CE conformity for approval type

Model Large
Platter size 280 x 293 mm
Capacity and minimum graduation Approval type Non approval type
15kg/5g(0-7.5kg),
10g(7.5~15kg)
30kg/10g(0~15kg),
20g(15~30kg)
15kg/5g
30kg/10g
Weighing method Electric resistance method
LCD panel Six digits(7-segment), character height 25 mm
Display information 6-digit weight, battery indicator,dicimal point, net weight indicator , stability indicator, minus sign, and unit of measurement
Net weight measurement Subtraction of tare weight by key input
Power Dry Cell 2 pieces (can be operated for 500 hours with alkaline dry D-Type batteries) or AC Adaptor (No Dry Cell and/or AC adaptor are included in the shipment) Auto Power Off function ( cb be set to 60 min., 20 min., or off)
Operational temperature -5°C ~ 40°C
Outer dimensions
(W x D x H)
286 x 363 x 102 mm
Weight 3.2kg (excluding batteries)
Approvals OIML,CE conformity for approval type