DACS-Z
Ishida DACS-Z Checkweigher achieves precise weighing accuracy at ultra fast speeds, up to 600 packages per minutes. Moreover, DACS-Z checkweigher offers network control options that maximize production efficiency.
| Model | DACS-Z-006-SB/SS-I | DACS-Z-030-SB/SS-I | |||||
|---|---|---|---|---|---|---|---|
| size: S | size: M | size: L | size: S | size: M | size: L | ||
| Weighing Capacity | 600 g | 3000 g | |||||
| Weighing Range | 6 - 600 g | 30 - 3000 g | |||||
| Weighing Speed (Max.)* | 600 / WPM | 400 / WPM | 320 / WPM | 400 / WPM | 320 / WPM | 220 / WPM | |
| Weighing Accuracy (3s)** | ±0.02 g ~ | ±0.1 g ~ | |||||
| Product Dimensions | Length | 46 ~ 120 mm | 46 ~ 220 mm | 46 ~ 320 mm | 58 ~ 210 mm | 76 ~ 320 mm | 76 ~ 450 mm |
| Width | 20 ~ 100 mm | 20 ~ 150 mm | 20 ~ 150 mm | 20 ~ 220 mm | 20 ~ 300 mm | 20 ~ 300 mm | |
| Height | 10 ~ 180 mm (130 mm with draft barrier cover installed) | 10 ~ 180 mm (130 mm with draft barrier cover installed) | |||||
| Conveyor Size | L : 153mm x W : 100 mm | L : 253 mm x W : 150 mm | L : 353 mm x W : 150 mm | L : 250 mm x W : 220 mm | L : 345 mm x W : 300 mm | L : 495 mm x W : 300 mm | |
| Weigh Sensor | Electromagnetic balance type | Electromagnetic balance type | |||||
| Minimum Graduation | 0.01 g | 0.05 g | |||||
| Setting Range | Target Weight | 0.01 ~ 600.00 g (Standard value + upper limit: 0.01 g increments) |
0.05 ~ 3000.00 g (Standard value + upper limit: 0.05 g increments) |
||||
| Belt Speed | 6 to 120 m / minute (in 1 m / minute increments) | 5 to 120 m / minute (in 1 m / minute increments) | |||||
| Zero Adjustment | Automatic zero-point correction (combined automatic & manual control) Operation start: Automatic control Operation stop: Combined automatic & manual control by pushbutton |
Automatic zero-point correction (combined automatic & manual control) Operation start: Automatic control Operation stop: Combined automatic & manual control by pushbutton |
|||||
| Presets | Max. 100 items | Max. 100 items | |||||
| Construction | IP-30 (international standard) | IP-30 (international standard) | |||||
| Temperature | 0 °C - 40 °C (relative humidity 30%–85%, no condensation) |
0 °C - 40 °C (relative humidity 30%–85%, no condensation) |
|||||
| Power Supply | 100 - 240 VAC 150 W 50 / 60 Hz Single-phase | 100 - 240 VAC 250 W 50 / 60 Hz Single-phase | |||||
| Main Body Weight | Approx. 70 kg | Approx. 80 kg | |||||
| *Stated performance is the theoretical maximum. Performance varies with product shape, operating conditions, and other factors. **Varies with product shape and condition. |
|||||||